UAE   ·   OMAN   ·   GCC / MENA ENGINEERINGProject Portal ↗My Workplace ↗
ARBON Energy SolutionsTalk to an Engineer ↗
PRODUCTS / OPTIFROST CHILLERS
OptiFrost — Chillers by ARBON

Cooling engineered for industry.
Efficiency engineered into the design.

Custom and process chiller engineering from ARBON, with configurable heat-rejection options for industrial facilities and demanding Gulf conditions.

DESIGN-TO-DUTY / OPTIFROST

Designed around your actual load.

Engineering evaluation considers evaporating and condensing conditions, process temperatures, utility limits, redundancy, service access and equipment lifetime.

Air-cooled / water-cooled configurationsWater & glycol process applicationsIndustrial control integrationSite-specific adiabatic option
Configuration and ratings to be confirmed by project datasheet, not indicative marketing capacities.
ENGINEERING-FIRST CHILLER SELECTION

What an OptiFrost package can include.

Equipment and controls are selected to the project—not assumed identical from one application to another.

01 / COOLING SYSTEM

Process-specific capacity

Selection against flow, temperature profile, duty cycle and design conditions.

02 / HEAT REJECTION

Site-appropriate configuration

Air- or water-cooled arrangements with optional adiabatic support where suitable.

03 / CONTROL & SAFETY

Engineered automation

Compressor staging, protections, sensors and integration with plant control systems.

04 / LIFECYCLE

Access and maintainability

Planning for commissioning, service clearance, maintenance and long-term support.

HOT-CLIMATE OPTION

Optional adiabatic condenser-air pre-cooling.

An adiabatic media section uses controlled water evaporation to cool the air entering the air-cooled condenser. Under favourable dry-bulb and wet-bulb conditions, this may reduce compressor lift, improve available cooling capacity and reduce energy demand compared with the same unit without pre-cooling.

  • Enable only when sensors indicate suitable ambient conditions.
  • Coordinate with condensing-pressure and chiller-capacity controls.
  • Specify water filtration, water-quality control, drainage and hygiene procedures.
  • Allow for water consumption and maintenance in lifecycle cost.
Request a design assessment ↗
ILLUSTRATIVE AIRFLOW / NOT TO SCALE
☀Outdoor airDry-bulb ambient
→
◉Adiabatic padControlled evaporation
→
❄Condenser coilPotentially cooler air

Not every climate or load yields a net saving. Final performance should be checked against duty, local weather, water quality, auxiliaries and manufacturer selections.

REQUEST A SELECTION

Tell us your cooling duty.

Application & process

Product, production line, cold storage or other process.

Design temperatures

Chilled-fluid supply/return, ambient design conditions and operating hours.

Capacity & utilities

Heat load, chilled water/glycol flow, electrical power, space and water availability.

Operation & reliability

Redundancy, controls, service conditions and future expansion.

Send us your requirements ↗